Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
4.
Am J Gastroenterol ; 119(2): 378-381, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37734341

RESUMO

INTRODUCTION: When initial resection of rectal neuroendocrine tumors (r-NETs) is not R0, persistence of local residue could lead to disease recurrence. This study aimed to evaluate the interest of systematic resection of non-R0 r-NET scars. METHODS: Retrospective analysis of all the consecutive endoscopic revisions and resections of the scar after non-R0 resections of r-NETs. RESULTS: A total of 100 patients were included. Salvage endoscopic procedure using endoscopic submucosal dissection or endoscopic full-thickness resection showed an R0 rate of near 100%. Residual r-NET was found in 43% of cases. DISCUSSION: In case of non-R0 resected r-NET, systematic scar resection by endoscopic full-thickness resection or endoscopic submucosal dissection seems necessary.


Assuntos
Ressecção Endoscópica de Mucosa , Tumores Neuroendócrinos , Neoplasias Retais , Humanos , Tumores Neuroendócrinos/cirurgia , Cicatriz/etiologia , Cicatriz/patologia , Estudos Retrospectivos , Resultado do Tratamento , Recidiva Local de Neoplasia/cirurgia , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Ressecção Endoscópica de Mucosa/métodos
5.
Endoscopy ; 56(3): 205-211, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37311544

RESUMO

BACKGROUND : Good submucosal exposure is key to successful endoscopic submucosal dissection (ESD) and can be achieved with various traction devices. Nevertheless, these devices have a fixed traction force that tends to decrease as the dissection progresses. In contrast, the ATRACT adaptive traction device increases traction during the procedure. METHODS : In this retrospective analysis of prospectively collected data (from a French database), we analyzed ESD procedures performed with the ATRACT device between April 2022 and October 2022. The device was used consecutively whenever possible. We collected details of lesion characteristics, procedural data, histologic outcomes, and clinical consequences for the patient. RESULTS : 54 resections performed in 52 patients by two experienced operators (46 procedures) and six novices (eight procedures) were analyzed. The ATRACT devices used were the ATRACT-2 (n = 21), the ATRACT 2 + 2 (n = 30), and the ATRACT-4 (n = 3). Four adverse events were observed: one perforation (1.9 %), which was closed endoscopically, and three delayed bleeding events (5.5 %). The R0 rate was 93 %, resulting in curative resection in 91 % of cases. CONCLUSION: ESD using the ATRACT device is safe and effective in the colon and rectum, but can also be used to assist with procedures in the upper gastrointestinal tract. It may be particularly useful in difficult locations.


Assuntos
Ressecção Endoscópica de Mucosa , Humanos , Ressecção Endoscópica de Mucosa/métodos , Estudos Retrospectivos , Reto , Dissecação/efeitos adversos , Dissecação/métodos , Tração , Resultado do Tratamento
8.
Cureus ; 15(9): e45507, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37868385

RESUMO

This study offers a thorough analysis of tibial pilon fractures, accounting for patient compliance, diverse treatment options, and soft tissue implications. The article discusses varied treatment pathways, ranging from single-stage interventions to two-stage methods for open fractures by presenting seven clinical cases. The emphasis is on the intricate interplay of trauma intensity, bone damage, and adjacent soft tissue in dictating treatment plans and patient outcomes. The challenges posed by non-compliant patients rejecting advised treatments are underscored, illuminating the inherent risks. Drawing from varied patient demographics, comorbidities, and fracture types, a comprehensive guide for clinicians emerges. The findings underscore the importance of a tailored, patient-centric approach, considering the multifaceted nature of ankle fractures, local soft tissue health, patient's overall well-being, and their adherence to the proposed treatment regimen.

13.
Surg Endosc ; 37(3): 2359-2366, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36229550

RESUMO

BACKGROUND: Esophageal endoscopic submucosal dissection (ESD) is the gold standard for the treatment of precancerous lesions or superficial esophageal cancers. This procedure is currently performed by expert endoscopists only, and poorly standardized. We aimed to assess the technical results and outcomes of a "tunnel + clip" strategy for esophageal ESD procedures performed by less experienced operators for the treatment of superficial neoplasms. METHODS: All consecutive esophageal ESDs performed with the "tunnel + clip" technique for patients with early esophageal cancer in 3 centers were enrolled. Procedural characteristics, clinical outcomes, and complications were recorded. RESULTS: Among 195 esophageal ESD procedures performed, early adenocarcinomas or high-grade dysplasia complicating Barrett's esophagus were predominant (132/195, 67.7%) compared with early squamous cell carcinomas (63/195, 32.3%). The en bloc, R0 and curative resection rates were 100% (195/195), 78.5% (153/195) and 67.2% (131/195), respectively. The mean rate of ESD was 29.7 mm2/min. One (0.5%) perprocedural perforation and 7 (3.6%) postprocedural bleedings occurred, all managed endoscopically. No delayed perforation occurred. Overall, 31 patients (31/195; 15.9%) of patients developed stenosis. CONCLUSIONS: The "tunnel + clip" strategy is safe, and allows to achieve high en bloc, R0 and curative resection rates. This standardized procedure could be used by physicians with little experience and might help spreading esophageal ESD in Western countries.


Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Humanos , Ressecção Endoscópica de Mucosa/métodos , Tração , Esofagoscopia/métodos , Resultado do Tratamento , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/patologia , Instrumentos Cirúrgicos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...